GDV
MATERIAL TESTING KIT
This
Kit contains a set of devices for testing different materials:
water and liquids, leafs, seeds, stones, etc. Herewith we
offer main ideas of its applications.
GDV
Material Testing kit include:
Syringe device
Cup device;
3 special electrode;
Glass GDV Electrode;
GDV device for measuring solid-state subjects.
MATERIAL
TESTING WITH GDV.
1.
Water and Liquids.
There are several installations for testing water, included
in this Kit. They are designed for different liquids.
Syringe
device (fig.1, fig.details)
Set
Up
1) Place Cover 1 at the GDV lens.
2) Screw metal part 3 into the part 2.
3) Insert syringe 4 into part 3 fully till stop.
4) Put circle plate 5 at the GDV window.
5) Place parts 2-4 at the cover 2.
6) By rotating part 3 in the holder 2 adjust the height position
where syringe's nose would be standing at the plate 5 and
syringe would be totally inside the part 3.
7) Guard the position by screw 6.
8) Connect the wire 7 to the grounding plug of the GDV camera
- Installation is ready for operation!
- Installation may be provided by KTI in ready - for - use
position.
Operation
1)
Take off the syringe from part 3.
2) Fill the syringe with water to the top.
3) By slightly moving the pump make a meniscus of water at
the syringe's nose. Meniscus should not be big - it should
not be a hanging drop.
4) Carefully insert syringe into the part 3 to the end.
5) Cover device with a cap to prevent extra light.
6) Make necessary snaps and check that water is not dropped
down. Recommended Code of Measurements is given below.
1.1.
Glass GDV Electrode
1)
Position the Glass Electrode 13 in the middle of the GDV lens.
2) Drop down the measured drop of water at the centre of Glass
13.
3) Place Cover 1 at the GDV lens.
4) Place parts 14, 15 at the Cover 1.
5) Connect wire 16 with the grounding plug of the GDV Camera.
6) Make necessary snaps.
1.2.
Cup device.
This
device is designed to study water stored in a close cup without
contact of a liquid with discharge area. Instead of cups may
be studied closed glass ampoules with liquids of the proper
size.
Set-up
1) Place the metal holder at the Cover 1, placed at the GDV
lens.
2) Insert plastic cup into the holder till it touches the
lens firmly.
3) Tube should be firmly positioned in the holder with metal
plates of the holder touching the tube.
4) Connect the wire to the plug of GDV.
Operation
1) Fill in the tube with water to the level above holder.
2) Cover cup with a plastic cover.
3) Make GDV snaps.
1.3.
Cup device with inside electrode
1)
After positioning cup in the holder fill in the water and
put on the cup the holder 12.
2) Connect the wire with GDV grounding plug.
3) Make GDV snaps.
1.4.
Measuring other objects.
You
can test practically any subject that feats to the GDV lens:
leaves, corns, minerals, etc. The common procedure is as follows:
1) Cover the GDV lens with plastic.
2) Put the sample at the GDV lens.
3) Cover the subject with plastic.
4) Attach one of the special electrodes or standing legs 13
above the plastic. In all cases electrode should touch the
object above the plastic.
5) Connect wire to the grounding plug of the GDV camera
6) Make the measurements.